TDM over IP User Manual V1.2
- 7 -
UPLINK port working in 100Mbps, and FDX is ON when UPLINK port
working in Full Duplex Mode.
Note: For F5-2315, only 1# E1 is available. For F5-2325, both 1# and 2# E1
are available.
6.4 Back view:
6.5 Port Description
z AC: AC 220V power input, DC –48V/-24V/-60V is also variable (Different
hole type);
z UPLNK: up link network port
z DATA: down link network port
z CLKIN: external clock input interface, 2Mhz TTL external synchronized
clock input
z CLKOUT: external clock output interface, 2Mhz TTL external synchronized
clock output
z IN: the 2M signal input
z OUT: the 2M signal output
z CONFIG: RS232 Console management port, private connected cable is
provided by the vendor.
7 Hardware installation and testing
7.1 installation preparation
Before installation, make sure all the listed conditions below are available.
1). Clean site
2) Dry environment (20 to 90% comparative humidity, no coagulation)
3) Good ventilation
4) Power source, 220VAC or other Power input.